Parameters of PD24 series

PD 24-02÷05 Models

Parameters

Units Condition PD24-02 PD24-05
Sensitive Area Diameter mm 0 0.2 0.5
Cut-off Wavelength mm at 10 % 2.4 2.4
Peak Wavelength mm > 90% 2.0-2.2 2.0-2.2
Responsivity A/W at lp 0.9-1.1 0.9-1.1
Dark Current mA VR= -0.2 V

= - 0.5 V

= - 1,0 V

0,7-3,0

1,5-6,0

2,0-10

3-10

6-15

8-20

Impedance kOhm VR= 10 mV 30-100 8-20
Capacitance pF VR=0 V

f=1 MHz

10-50 80-400
Rise and Fall Time ns (0V; 50 Ohm) 2-10 15-80
Detectivity cm.Hz1/2/W (lp,1000,1) (1-3)*1010 (3-5)*1010

Package

PD24-XX

PD24-XX-PR

PD24-XX-PRW

PD XX-TEC

PD XX-TEC-PR

TO-18

TO-18+PR

TO-18+PRW

TO-5

TO-5+PR

TO-18

TO-18+PR

TO-18+PRW

TO-5

TO-5+PR


PD 24-10ч20 Models

Parameters

Units Condition PD24-10 PD24-20
Sensitive Area Diameter mm 0 1.0 2.0
Cut-off Wavelength mm at 10 % 2.4 2.4
Peak Wavelength mm > 90% 2.0-2.2 2.0-2.2
Responsivity A/W at lp 0.9-1.1 0.9-1.1
Dark Current mA VR= -0.2 V

= - 0.5 V

= - 1,0 V

30-60

50-150

70-200

50-100

100-200

150-300

Impedance kOhm VR= 10 mV 0.7-4.0 0.3-1.5
Capacitance nF VR=0 V

f=1 MHz

0.5-1.5 1.2-3.0
Rise and Fall Time ns (0V; 50 Ohm) 100-200 120-400
Detectivity cm.Hz1/2/W (lp,1000,1) (3-5)*1010 (5-8)*1010

Package

PD24-XX

PD24-XX-PR

PD24-XX-PRW

PD XX-TEC

PD XX-TEC-PR

TO-18

TO-18+PR

TO-18+PRW

TO-5

TO-5+PR

TO-5

TO-5+PR

TO-5+PRW

TO-5

TO-5+PR